您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
-
我的賬號
註冊
登錄
忘記密碼?
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
CAD模型
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
CAD模型
登錄
註冊
忘記密碼?
български
čeština
Deutsch
English (United Kingdom)
English (United States)
español
français
italiano
日本語
한국어
polski
português
русский
Türkçe
中文
中文 (繁體)
Catalog navigation
所有產品目錄
幾何搜索
草圖搜索
變量搜索
認證的產品目錄
按照分類
按照國家
按照標準
可提供的產品目錄語言:
English
English
Gira 217600
Gira
Powered by
CAD模型選擇
All
Electro
All
Electro
{gira/gira_217600.prj},{NB=Gira_217600},{ORDERNO=Gira_217600},{BUS_CONNECTION_INCLUDED=0},{BUS_SYSTEM_KNX=1},{BUS_SYSTEM_KNX_RADIO=0},{BUS_SYSTEM_LON=0},{BUS_SYSTEM_POWERNET=0},{BUS_SYSTEM_RADIO_FREQUENT=0},{COST=0},{CUT_WITH_VOIDS_WHEN_LOADED=0},{DEFAULT_ELEVATION=1219.200},{HOST=5},{MAINTAIN_ANNOTATION_ORIENTATION=0},{MASSUNIT=1},{PART_TYPE=0},{RADIO_FREQUENT_BIDIRECTIONAL=0},{ROOM_CALCULATION_POINT=0},{ROUND_CONNECTOR_DIMENSION=1},{SHARED=0},{BIM=https://media.stage.bim.site/public/gira/ad86d9f/Stellenantrieb.rfa},{DATA_SHEET=https://katalog.gira.de/en/download.html?artikelnr=217600},{DEGREE_OF_PROTECTION__IP_=IP20}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
HELP_VARIABLE
Company
Gira
Description
Gira_217600
Bill of material
Gira_217600
ORDERNO
Gira_217600
BIM
bim
https://media.stage.bim.site/public/gira/ad86d9f/Stellenantrieb.rfa
BUS_CONNECTION_INCLUDED
bus connection included
0
BUS_SYSTEM_KNX
bus system knx
1
BUS_SYSTEM_KNX_RADIO
bus system knx radio
0
BUS_SYSTEM_LON
bus system lon
0
BUS_SYSTEM_POWERNET
bus system powernet
0
BUS_SYSTEM_RADIO_FREQUENT
bus system radio frequent
0
COST
cost
0
CUT_WITH_VOIDS_WHEN_LOADED
cut with voids when loaded
0
DATA_SHEET
data sheet
https://katalog.gira.de/en/download.html?artikelnr=217600
DEFAULT_ELEVATION
default elevation
1219.200
DEGREE_OF_PROTECTION__IP_
degree of protection (ip)
IP20
DESCRIPTION
description
KNX servo 3 KNX,KNX servo 3,,,Features:,- Electric motor-driven servo with one binary input (zero-voltage) for mounting on thermostat valve bases (recommended: Heimeier) for controlling heating or cooling systems.,- Suitable for room temperature control, e.g. on radiators, convector heaters or heating circuit distributors on floor heating, etc.,- Screwed onto valve head.,- M30 × 1.5 mm connection.,- Integrated bus coupler. The servo is a proportional drive and can be directly integrated into the KNX system (without additional bus coupler).,- Supply voltage is drawn from the KNX system.,- Integrated temperature sensor.,- Integrated room temperature controller.,- Mechanical indicator for valve travel.,- Automatic detection of valve travel.,- One input. This can be used as a binary input or for connecting an external temperature sensor with the following functions:, Switching, dimming, blind, as dimming value transmitter, as brightness value transmitter, as light scene auxiliary unit with and without memory function, as remote temperature sensor or as temperature limiter for underfloor heating.,- Switching function: two independent switching objects are available for each input (switching commands can parameterised individually), command for leading and trailing edge can be set independently (ON, OFF, CHANGE, no reaction).,- Dimming function: Single and double-surface operation, time between dimming and switching, telegram repetition and stop-telegram transmission possible.,- Blind function: Command can be set with rising edge (no function, UP, DOWN, CHANGE), operating concept can be configured (Step - Move - Step or Move - Step), time between short and long-term operation can be set (only with Step - Move - Step), slat adjustment time can be set.,- Value transmitter function: Edge (button as NO contact, button as NC contact, switch) and value with edge can be configured, value adjustment by pressing and holding a button for value transmitters possible.,- Lighting scenario auxiliary unit with or without memory function.,- Can be used in a heating circuit distributor.,- Protection against jammed valves,- Corrected variable (1 bit or 1 byte).,- Cyclical monitoring of the corrected variable.,- Fault message object for drive faults.,- Emergency operation via internal temperature sensor.,- 2 forced settings or 1 forced setting and 1 limit value object can be set.,- Minimum and maximum variable limit can be set.,,Notes :,- With the default setting, the servo fits on Heimeier valve bases. Use an adapter for valve bases of other manufacturers.
DESIGN_OPTION
design option
-1
GTIN
gtin
4010337019374
HAN
han
217600
HOST
host
5
MAINTAIN_ANNOTATION_ORIENTATION
maintain annotation orientation
0
MANUFACTURER
manufacturer
Gira
MASSUNIT
massunit
1
MOUNTING_METHOD
mounting method
Radiator valve
OTHER_BUS_SYSTEMS
other bus systems
None
PART_TYPE
part type
0
PRODUCTWEBSITE
productwebsite
http://katalog.gira.de/en/datenblatt.html?artikelnr=217600
RADIO_FREQUENT_BIDIRECTIONAL
radio frequent bidirectional
0
ROOM_CALCULATION_POINT
room calculation point
0
ROUND_CONNECTOR_DIMENSION
round connector dimension
1
SHARED
shared
0
TYPNAME
typname
Servo 3 KNX
URL
url
https://www.gira.de/
VERSION
version
2017
NAME
name
Gira_217600